Protective Devices - MCB

Our range of cicuit breakers within our protective devices section meet road agency criteria.

  • MCB ? BM SERIES BMS0 4,5 kA
  • MCB ? BM SERIES BMS0 6 kA
  • MCB ? BM SERIES BMS0 10 kA
  • MCB ? SERIES BMS0-DC
  • MCB ? BS 1+N SERIES SI-E 4,5 kA / 6 kA
  • MCB ? HIGH CURRENT SERIES BR 10 kA
  • MCB ? HIGH CURRENT BR SERIES 15 ? 25 kA

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – BM SERIES BMS0 4,5 kA

  • Rated voltage/frequency
    • 230 V/400 V AC 50/60 Hz, 240 V/415 V AC 50/60 Hz ME version
  • Rated breaking capacity
    • 4.5 kA according to IEC/EN 60 898
  • Rated breaking capacity DC
    • max 48 V one pole
  • Tripping characteristics
    • B, C according to EN 60 898
  • Back up fuse
    • 80 A gG max (>45 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Operation temperature
    • -40 deg C to +75 deg C
  • Ambient temperature
    • +50 deg C for ME-type
  • Selectivity class:
    • 3
  • Degree of protection
    • IP20
  • Endurance
    • > 8000 Operating cycles
  • Window with contact position indicator (Red/Green for each pole)
  • Terminal capacity
    • 1 mm2 - 25 mm2 (except 1P+N)
  • Additional connection cabability for busbar block system
  • DIN rail mounting (EN 50 022)
  • Finger and hand touch safe according to BVG A3/OVE-EN 6

SINGLE POLE RATED

CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
6 A BM418106 BM417106 - BM417106ME
10 A BM418110 BM417110 - BM417110ME
16 A BM418116 BM417116 - BM417116ME
20 A BM418120 BM417120 - BM417120ME
25 A BM418125 BM417125 - BM417125ME
32 A BM418132 BM417132 - BM417132ME
40 A BM418140 BM417140 - BM417140ME
50 A - BM417150 - -
63 A - BM417163 - -

SINGLE POLE + NEUTRAL

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
6 A BM418606 BM417606 - -
10 A BM418610 BM417610 - -
16 A BM418616 BM417616 - -
20 A BM418620 BM417620 - -
25 A BM418625 BM417625 - -
32 A BM418632 BM417632 - -
40 A BM418640 BM417640 - -
50 A - BM417650 - -
63 A - BM417663 - -

DOUBLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
6 A BM418206 BM417206 - BM417206ME
10 A BM418210 BM417210 - BM417210ME
16 A BM418216 BM417216 - BM417216ME
20 A BM418220 BM417220 - BM417220ME
25 A BM418225 BM417225 - BM417225ME
32 A BM418232 BM417232 - BM417232ME
40 A BM418240 BM417240 - BM417240ME
50 A - BM417250 - -
63 A - BM417263 - -

TRIPLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
6 A BM418306 BM417306 - BM417306ME
10 A BM418310 BM417310 - BM417310ME
16 A BM418316 BM417316 - BM417316ME
20 A BM418320 BM417320 - BM417320ME
25 A BM418325 BM417325 - BM417325ME
32 A BM418332 BM417332 - BM417332ME
40 A BM418340 BM417340 - BM417340ME
50 A - BM417350 - -
63 A - BM417363 - -

TRIPLE POLE + NEUTRAL RATED

CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
6 A BM418806 BM417806 - BM417806ME
10 A BM418810 BM417810 - BM417810ME
16 A BM418816 BM417816 - BM417816ME
20 A BM418820 BM417820 - BM417820ME
25 A BM418825 BM417825 - BM417825ME
32 A BM418832 BM417832 - BM417832ME
40 A BM418840 BM417840 - BM417840ME
50 A - BM417850 - -
63 A - BM417863 - -

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – BM SERIES BMS0 6 kA

  • Rated voltage/frequency
    • 230 V/400 V AC 50/60 Hz, 240 V/415 V AC 50/60 Hz ME version
  • Rated breaking capacity
    • 6 kA according to IEC/EN 60 898, 10 kA according to IEC/EN 60 947-2
  • Rated breaking capacity DC
    • max 48 V one pole
  • Tripping characteristics
    • B, C according to EN 60 898
  • Back up fuse
    • 100 A gG max (>10 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Operation temperature
    • -40 deg C to +75 deg C
  • Ambient temperature
  • +50 deg C for ME-type
  • Selectivity class
    • 3 • Degree of protection: IP20
  • Endurance
    • > 8000 Operating cycles
  • Window with contact position indicator (Red/Green for each pole)
  • Terminal capacity
  • 1 mm2 - 25 mm2
  • Additional connection cabability for busbar block system
  • DIN rail mounting (EN 50 022)
  • Finger and hand touch safe according to BVG A3/OVE-EN 6

SINGLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617102 - BM617102ME
4 A - BM617104 - BM617104ME
6 A BM618106 BM617106 - BM617106ME
10 A BM618110 BM617110 - BM617110ME
16 A BM618116 BM617116 - BM617116ME
20 A BM618120 BM617120 - BM617120ME
25 A BM618125 BM617125 - BM617125ME
32 A BM618132 BM617132 - BM617132ME
40 A BM618140 BM617140 - BM617140ME
50 A BM618150 BM617150 - BM617150ME
63 A BM618163 BM617163 - BM617163ME

SINGLE POLE + NEUTRAL

 

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617602 - -
4 A - BM617604 - -
6 A BM618606 BM617606 - -
10 A BM618610 BM617610 - -
16 A BM618616 BM617616 - -
20 A BM618620 BM617620 - -
25 A BM618625 BM617625 - -
32 A BM618632 BM617632 - -
40 A BM618640 BM617640 - -
50 A - BM617650 - -
63 A - BM617663 - -

DOUBLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617202 - BM617202ME
4 A - BM617204 - BM617204ME
6 A BM618206 BM617206 - BM617206ME
10 A BM618210 BM617210 - BM617210ME
16 A BM618216 BM617216 - BM617216ME
20 A BM618220 BM617220 - BM617220ME
25 A BM618225 BM617225 - BM617225ME
32 A BM618232 BM617232 - BM617232ME
40 A BM618240 BM617240 - BM617240ME
50 A BM618250 BM617250 - BM617250ME
63 A BM618263 BM617263 - BM617263ME

TRIPLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617302 - BM617302ME
4 A - BM617304 - BM617304ME
6 A BM618306 BM617306 - BM617306ME
10 A BM618310 BM617310 - BM617310ME
16 A BM618316 BM617316 - BM617316ME
20 A BM618320 BM617320 - BM617320ME
25 A BM618325 BM617325 - BM617325ME
32 A BM618332 BM617332 - BM617332ME
40 A BM618340 BM617340 - BM617340ME
50 A BM618350 BM617350 - BM617350ME
63 A BM618363 BM617363 - BM617363ME

TRIPLE POLE + NEUTRAL

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617802 - BM617802ME
4 A - BM617804 - BM617804ME
6 A BM618806 BM617806 - BM617806ME
10 A BM618810 BM617810 - BM617810ME
16 A BM618816 BM617816 - BM617816ME
20 A BM618820 BM617820 - BM617820ME
25 A BM618825 BM617825 - BM617825ME
32 A BM618832 BM617832 - BM617832ME
40 A BM618840 BM617840 - BM617840ME
50 A BM618850 BM617850 - BM617850ME
63 A BM618863 BM617863 - BM617863ME

FOUR POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM617402 - -
4 A - BM617404 - -
6 A - BM617406 - -
10 A - BM617410 - -
16 A - BM617416 - -
20 A - BM617420 - -
25 A - BM617425 - -
32 A - BM617432 - -
40 A - BM617440 - -
50 A - BM617450 - -
63 A - BM617463 - -

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – BM SERIES BMS0 10 kA

  • Rated voltage/frequency
    • 230 V/400 V AC 50/60 Hz
  • Rated breaking capacity
    • 10 kA according to IEC/EN 60 898, 15 kA according to IEC/EN 60 947-2
  • Rated breaking capacity DC
    • max 48 V one pole
  • Tripping characteristics
    • B, C, D according to EN 60 898
  • Back up fuse
    • 100 A gG max (>10 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Operation temperature
    • -40 deg C to +75 deg C
  • Ambient temperature
    • +50 deg C for ME-type
  • Selectivity class
    • 3
  • Degree of protection
    • IP20
  • Endurance
    • > 8000 Operating cycles
  • Window with contact position indicator (Red/Green for each pole)
  • Terminal capacity
    • 1 mm2 - 25 mm2 (except 1P+N)
  • Additional connection cabability for busbar block system
  • DIN rail mounting (EN 50 022)
  • Finger and hand touch safe according to BVG A3/OVE-EN 6

SINGLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM017102 BM019102 BM017102ME
4 A - BM017104 BM019104 BM017104ME
6 A BM018106 BM017106 BM019106 BM017106ME
10 A BM018110 BM017110 BM019110 BM017110ME
16 A BM018116 BM017116 BM019116 BM017116ME
20 A BM018120 BM017120 BM019120 BM017120ME
25 A BM018125 BM017125 BM019125 BM017125ME
32 A BM018132 BM017132 BM019132 BM017132ME
40 A BM018140 BM017140 BM019140 BM017140ME
50 A BM018150 BM017150 BM019150* BM017150ME
63 A BM018163 BM017163 BM019163* BM017163ME

SINGLE POLE + NEUTRAL

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A BM018602 BM017602 - -
4 A BM018604 BM017604 - -
6 A BM018606 BM017606 - -
10 A BM018610 BM017610 - -
16 A BM018616 BM017616 - -
20 A BM018620 BM017620 - -
25 A BM018625 BM017625 - -
32 A BM018632 BM017632 - -
40 A BM018640 BM017640 - -
50 A BM018650 BM017650 - -
63 A BM018663 BM017663 - -

DOUBLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM017202 BM019202 BM017202ME
4 A - BM017204 BM019204 BM017204ME
6 A BM018206 BM017206 BM019206 BM017206ME
10 A BM018210 BM017210 BM019210 BM017210ME
16 A BM018216 BM017216 BM019216 BM017216ME
20 A BM018220 BM017220 BM019220 BM017220ME
25 A BM018225 BM017225 BM019225 BM017225ME
32 A BM018232 BM017232 BM019232 BM017232ME
40 A BM018240 BM017240 BM019240 BM017240ME
50 A BM018250 BM017250   BM017250ME
63 A BM018263 BM017263   BM017263ME

TRIPLE POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM017302 BM019302 BM017302ME
4 A - BM017304 BM019304 BM017304ME
6 A BM018306 BM017306 BM019306 BM017306ME
10 A BM018310 BM017310 BM019310 BM017310ME
16 A BM018316 BM017316 BM019316 BM017316ME
20 A BM018320 BM017320 BM019320 BM017320ME
25 A BM018325 BM017325 BM019325 BM017325ME
32 A BM018332 BM017332 BM019332 BM017332ME
40 A BM018340 BM017340 BM019340 BM017340ME
50 A BM018350 BM017350 BM019350* BM017350ME
63 A BM018363 BM017363 BM019363* BM017363ME

TRIPLE POLE + NEUTRAL

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - BM017802 BM019802 BM017802ME
4 A - BM017804 BM019804 BM017804ME
6 A BM018806 BM017806 BM019806 BM017806ME
10 A BM018810 BM017810 BM019810 BM017810ME
16 A BM018816 BM017816 BM019816 BM017816ME
20 A BM018820 BM017820 BM019820 BM017820ME
25 A BM018825 BM017825 BM019825 BM017825ME
32 A BM018832 BM017832 BM019832 BM017832ME
40 A BM018840 BM017840 BM019840 BM017840ME
50 A BM018850 BM017850 BM019850* BM017850ME
63 A BM018863 BM017863 BM019863* BM017863ME

FOUR POLE

RATED CURRENT TYPE B / CAL. TEMP 30°C TYPE C / CAL. TEMP 30°C TYPE D / CAL. TEMP 30°C TYPE C / CAL. TEMP 40°C
2 A - - - -
4 A - - - -
6 A - BM017406 BM019406 -
10 A - BM017410 BM019410 -
16 A - BM017416 BM019416 -
20 A - BM017420 BM019420 -
25 A - BM017425 BM019425 -
32 A - BM017432 BM019432 -
40 A - BM017440 BM019440 -
50 A - BM017450   -
63 A - BM017463   -

*only according to EN 60947-2

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – SERIES BMS0-DC

  • Rated voltage
    • 220 V DC per pole; T = 4 ms
  • Switching capacity
    • 6 kA acc. to IEC/EN 60898
  • Back-up fuse max.
    • 100 A gL
  • Tripping characteristics
    • C
  • Terminal capacity
    • 1-25 mm2
  • Take in account polarity
  • Designed for use in DC installations

SINGLE POLE

RATED CURRENT TYPE ORDER NO.
2 A BMS0-C 2/1-DC BM015102
6 A BMS0-C 6/1-DC BM015106
10 A BMS0-C 10/1-DC BM015110
16 A BMS0-C 16/1-DC BM015116
20 A BMS0-C 20/1-DC BM015120
25 A BMS0-C 25/1-DC BM015125
32 A BMS0-C 32/1-DC BM015132
40 A BMS0-C 40/1-DC BM015140
50 A BMS0-C 50/1-DC BM015150

DOUBLE POLE

RATED CURRENT TYPE ORDER NO.
2 A BMS0-C 2/2-DC BM015202
6 A BMS0-C 6/2-DC BM015206
10 A BMS0-C 10/2-DC BM015210
16 A BMS0-C 16/2-DC BM015216
20 A BMS0-C 20/2-DC BM015220
25 A BMS0-C 25/2-DC BM015225
32 A BMS0-C 32/2-DC BM015232
40 A BMS0-C 40/2-DC BM015240
50 A BMS0-C 50/2-DC BM015250

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – BS 1+N SERIES SI-E 4,5 kA / 6 kA

  • 1+N at only 1 space unit, Selectivity class
    • 3
  • Rated voltage/frequency
    • 230 V AC, 50/60 Hz
  • Rated breaking capacity
    • 4,5 kA according to IEC/EN 60 898, 6 kA according to IEC/EN 60 898
  • Rated breaking capacity DC
    • max 48 V
  • Tripping characteristics
    • B, C according to EN 60 898
  • Back up fuse
    • 4,5 kA - Type 80 A gG max (>4,5 kA), 6 kA - Type100 A gG max (>10 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Operation temperature
    • -40 deg C to +75 deg C

4,5 kA

RATED CURRENT TYPE B CAL. TEMP 30°C TYPE C CAL. TEMP 30°C
2 A - BS417502
4 A - BS417504
6 A BS418506 BS417506
10 A BS418510 BS417510
16 A BS418516 BS417516
20 A BS418520 BS417520
25 A BS418525 BS417525
32 A BS418532 BS417532
40 A BS418540 BS417540

6 kA

RATED CURRENT TYPE B CAL. TEMP 30°C TYPE C CAL. TEMP 30°C
2 A - BS017502
4 A - BS017504
6 A BS018506 BS017506
10 A BS018510 BS017510
16 A BS018516 BS017516
20 A BS018520 BS017520
25 A BS018525 BS017525
32 A BS018532 BS017532
40 A BS018540 BS017540

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – HIGH CURRENT SERIES BR 10 kA

  • Rated voltage/frequency
    • 230 V/400 V AC 50/60 Hz
  • Rated breaking capacity
    • 10 kA according to marking
  • Rated breaking capacity DC
    • max 60 V one pole
  • Tripping characteristics
    • C & D according to EN 60 898
  • Back up fuse
    • 200 A gG max (>20 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Endurance
    • > 20,000 Operating cycles
  • Window with contact position indicator (Red/Green for each pole)
  • Terminal capacity
    • 2,5 mm2 - 50 mm2
  • Double break switching contact
  • DIN rail mounting (EN 50 022)

SINGLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
80 A BR971800 -
100 A BR971910 -
125 A BR971912 -

DOUBLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
80 A BR972800 -
100 A BR972910 -
125 A BR972912 -

TRIPLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
80 A BR973800 -
100 A BR973910 -
125 A BR973912 -

TRIPLE POLE + NEUTRAL

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
80 A BR978800 -
100 A BR978910 -
125 A BR978912 -

MCB

Protective devices (PDF datasheet)Product enquiry and further information (Contact us form)

MCB – HIGH CURRENT BR SERIES 15 – 25 kA

  • Rated voltage/frequency
    • 230 V/400 V AC 50/60 Hz
  • Rated breaking capacity
    • 15-25 kA according to marking
  • Rated breaking capacity DC
    • max 60 V one pole
  • Tripping characteristics
    • C & D according to EN 60 898
  • Back up fuse
    • 200 A gG max (>20 kA)
  • Tripping temperature
    • -5 deg C to +40 deg C
  • Degree of protection
    • IP20
  • Endurance
    • > 20,000 Operating cycles
  • Window with contact position indicator (Red/Green for each pole)
  • Terminal capacity
    • 2,5 mm2 - 50 mm2
  • Double break switching contact
  • DIN rail mounting (EN 50 022)

SINGLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
20 A BR571200 BR591200
25 A BR571250 BR591250
32 A BR571320 BR591320
40 A BR571400 BR591400
50 A BR571500 BR591500
63 A BR571630 BR591630
80 A BR571800 BR591800
100 A BR571910 BR591910
125 A BR571912 -

DOUBLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
20 A BR572200 BR592200
25 A BR572250 BR592250
32 A BR572320 BR592320
40 A BR572400 BR592400
50 A BR572500 BR592500
63 A BR572630 BR592630
80 A BR572800 BR592800
100 A BR572910 BR592910
125 A BR572912 -

TRIPLE POLE

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
20 A BR573200 BR593200
25 A BR573250 BR593250
32 A BR573320 BR593320
40 A BR573400 BR593400
50 A BR573500 BR593500
63 A BR573630 BR593630
80 A BR573800 BR593800
100 A BR573910 BR593910
125 A BR573912 -

TRIPLE POLE + NEUTRAL

RATED CURRENT TYPE C CAL. TEMP 30°C TYPE D CAL. TEMP 30°C
20 A BR578200 BR598200
25 A BR578250 BR598250
32 A BR578320 BR598320
40 A BR578400 BR598400
50 A BR578500 BR598500
63 A BR578630 BR598630
80 A BR578800 BR598800
100 A BR578910 BR598910
125 A BR578912 -

Product enquiry and further information