MC - Frame Size 2 / Up to 300A

MC - Frame Size 2 / Up to 300A

CIRCUIT BREAKER 3 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE TYPES MC2B-A, MC2C-A, MC2N-A, MC2H-A

  • For system and line protection
  • Adjustable overload releaser:I 0,8 – 1 x In (factory setting 0,8 x In)
  • Adjustable short-circuit releasei:I 6 – 10 x In (factory setting 6 x In); except MC.-A40: 8 - 10 x In
  • Screw terminals as standard, box terminals as accessories
  • Breaking capacity 25 / 36 / 50 / 150 kA at 415 V 50/60 Hz
  • Meets IEC/EN 60947-2
  • Rated uninterrupted current = Rated current

CIRCUIT BREAKER 3 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE TYPES MC2B-A, MC2C-A, MC2N-A, MC2H-A

RATED CURRENT/ BREAKING CAPACITY

  • SETTING RANGE
    • OVERLOAD- RELEASE (A)
    • SHORT CIRCUIT- RELEASE (A)
    • TYPE
    • ORDER NO.

3 POLE (BASIC BREAKING CAPACITY) 25 kA

  • 160 A/25 kA
    • 125…160
    • 960…1600
    • MC2B-A160
    • MC216131
  • 200 A/25 kA
    • 160…200
    • 1200…2000
    • MC2B-A200
    • MC220131
  • 250 A/25 kA
    • 200…250
    • 1500…2500
    • MC2B-A250
    • MC225131
  • 300 A/25 kA
    • 240…300
    • 2000…2500
    • MC2B-A300
    • MC230131

3 POLE (COMFORT BREAKING CAPACITY) 36 kA

  • 160 A/36 kA
    • 125…160
    • 960…1600
    • MC2C-A160
    • MC216431
  • 200 A/36 kA
    • 160…200
    • 1200…2000
    • MC2C-A200
    • MC220431
  • 250 A/36 kA
    • 200…250
    • 1500…2500
    • MC2C-A250
    • MC225431
  • 300 A/36 kA
    • 240…300
    • 2000…2500
    • MC2C-A300
    • MC230431

3 POLE (NORMAL BREAKING CAPACITY) 50 kA

  • 160 A/50 kA
    • 125…160
    • 960…1600
    • MC2N-A160
    • MC216231
  • 200 A/50 kA
    • 160…200
    • 1200…2000
    • MC2N-A200
    • MC220231
  • 250 A/50 kA
    • 200…250
    • 1500…2500
    • MC2N-A250
    • MC225231
  • 300 A/50 kA
    • 240…300
    • 2000…2500
    • MC2N-A300
    • MC230231

3 POLE (HIGH BREAKING CAPACITY) 150 kA

  • 20 A/150 kA
    • 15…20
    • fix 350
    • MC2H-A20
    • MC202331
  • 25 A/150 kA
    • 20…25
    • fix 350
    • MC2H-A25
    • MC205331
  • 32 A/150 kA
    • 25…32
    • fix 350
    • MC2H-A32
    • MC232331
  • 40 A/150 kA
    • 32…40
    • 320…400
    • MC2H-A40
    • MC240331
  • 50 A/150 kA
    • 40…50
    • 300…500
    • MC2H-A50
    • MC250331
  • 63 A/150 kA
    • 50…63
    • 380…630
    • MC2H-A63
    • MC263331
  • 80 A/150 kA
    • 63…80
    • 480…800
    • MC2H-A80
    • MC280331
  • 100 A/150 kA
    • 80…100
    • 600…1000
    • MC2H-A100
    • MC210331
  • 125 A/150 kA
    • 100…125
    • 750…1250
    • MC2H-A125
    • MC212331
  • 160 A/150 kA
    • 125…160
    • 960…1600
    • MC2H-A160
    • MC216331
  • 200 A/150 kA
    • 160…200
    • 1200…2000
    • MC2H-A200
    • MC220331
  • 250 A/150 kA
    • 200…250
    • 1500…2500
    • MC2H-A250
    • MC225331
  • 300 A/150 kA
    • 240…300
    • 2000…2500
    • MC2H-A300
    • MC230331

CIRCUIT BREAKER 3 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE    TYPES MC2B-A, MC2C-A, MC2N-A, MC2H-A

CIRCUIT BREAKER 4 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE TYPES MC2B-4-A, MC2N-4-A, MC2H-4-A

  • For system and line protection
  • Adjustable overload releaser:I 0,8 – 1 x In (factory setting 0,8 x In)
  • Adjustable short-circuit releasei:I 6 – 10 x In (factory setting 6 x In); except MC.-A40: 8 - 10 x In
  • Screw terminals as standard, box terminals as accessories
  • Breaking capacity 25 / 50 / 150 kA at 415 V 50/60 Hz
  • Meets IEC/EN 60947-2
  • Rated uninterrupted current = Rated current

CIRCUIT BREAKER 4 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE TYPES MC2B-4-A, MC2N-4-A, MC2H-4-A

RATED CURRENT/ BREAKING CAPACITY

  • SETTING RANGE
    • OVERLOAD- RELEASE (A)
    • SHORT CIRCUIT- RELEASE (A)
    • TYPE
    • ORDER NO.

4 POLE (BASIC BREAKING CAPACITY) 25 kA

  • 160 A/25 kA
    • 125…160
    • 960…1600
    • MC2B-4-A160
    • MC216141
  • 200 A/25 kA
    • 160…200
    • 1200…2000
    • MC2B-4-A200
    • MC220141
  • 250 A/25 kA
    • 200…250
    • 1500…2500
    • MC2B-4-A250
    • MC225141
  • 300 A/25 kA
    • 240…300
    • 2000…2500
    • MC2B-4-A300
    • MC230141

4 POLE (NORMAL BREAKING CAPACITY) 50 kA

  • 160 A/50 kA
    • 125…160
    • 960…1600
    • MC2N-4-A160
    • MC216241
  • 200 A/50 kA
    • 160…200
    • 1200…2000
    • MC2N-4-A200
    • MC220241
  • 250 A/50 kA
    • 200…250
    • 1500…2500
    • MC2N-4-A250
    • MC225241
  • 300 A/50 kA
    • 240…300
    • 2000…2500
    • MC2N-4-A300
    • MC230241

4 POLE (HIGH BREAKING CAPACITY) 150 kA

  • 20 A/150 kA
    • 15…20
    • fix 350
    • MC2H-4-A20
    • MC202341
  • 25 A/150 kA
    • 20…25
    • fix 350
    • MC2H-4-A25
    • MC205341
  • 32 A/150 kA
    • 25…32
    • fix 350
    • MC2H-4-A32
    • MC232341
  • 40 A/150 kA
    • 32…40
    • 320…400
    • MC2H-4-A40
    • MC240341
  • 50 A/150 kA
    • 40…50
    • 300…500
    • MC2H-4-A50
    • MC250341
  • 63 A/150 kA
    • 50…63
    • 380…630
    • MC2H-4-A63
    • MC263341
  • 80 A/150 kA
    • 63…80
    • 480…800
    • MC2H-4-A80
    • MC280341
  • 100 A/150 kA
    • 80…100
    • 600…1000
    • MC2H-4-A100
    • MC210341
  • 125 A/150 kA
    • 100…125
    • 750…1250
    • MC2H-4-A125
    • MC212341
  • 160 A/150 kA
    • 125…160
    • 960…1600
    • MC2H-4-A160
    • MC216341
  • 200 A/150 kA
    • 160…200
    • 1200…2000
    • MC2H-4-A200
    • MC220341
  • 250 A/150 kA
    • 200…250
    • 1500…2500
    • MC2H-4-A250
    • MC225341
  • 300 A/150 kA
    • 240…300
    • 2000…2500
    • MC2H-4-A300
    • MC230341

CIRCUIT BREAKER 4 POLE UP TO 300A WITH THERMAL MAGNETIC RELEASE    TYPES MC2B-4-A, MC2N-4-A, MC2H-4-A

CIRCUIT BREAKER UP TO 250A 3-/4 POLE WITH DELAYED ELECTRONIC RELEASE TYPES MC2N-VE, MC2H-VE, MC2N-4-VE, MC2H-4-VE

  • System and line protection
  • Selective and generator protection
  • 3 and 4 pole versions
  • RMS value and “thermal memory”
  • Adjustable overload releaser:I 0,5 – 1 x In (factory setting 0,8 x In)
  • Adjustable time delay setting to overcome current peaksr:t 2 – 20 s at 6 x Ir as well as infinity (factory setting 10s)
  • Adjustable delayed short-circuit releasessd:I 2 – 10 x Ir (factory setting 6 x Ir)
  • Adjustable time delay tsd: Levels: 0, 20, 60, 100, 200, 300, 500, 750, 1000 ms (factory setting 0)
  • Non-delayed short-circuit releasei:I permanent 12 x In)
  • Screw terminals as standard, box terminals as accessories
  • Meets IEC/EN 60947-2
  • Rated uninterrupted current = Rated current

CIRCUIT BREAKER UP TO 250A 3-/4 POLE WITH DELAYED ELECTRONIC RELEASE TYPES MC2N-VE, MC2H-VE, MC2N-4-VE, MC2H-4-VE

RATED CURRENT/ BREAKING CAPACITY

  • SETTING RANGE
    • OVERLOAD- RELEASE (A)
    • SHORT-CIRCUIT UNDELAYED (A)
    • RELEASE DELAYED (A)
    • TYPE
    • ORDER NO.

3 POLE (NORMAL BREAKING CAPACITY) 50 kA

  • 100 A/50 kA
    • 50…100
    • 1200
    • 100…1000
    • MC2N-VE100
    • MC210233
  • 160 A/50 kA
    • 80…160
    • 1920
    • 160…1600
    • MC2N-VE160
    • MC216233
  • 250 A/50 kA
    • 125…250
    • 3000
    • 250…2500
    • MC2N-VE250
    • MC225233

3 POLE (HIGH BREAKING CAPACITY) 150 kA

  • 100 A/150 kA
    • 50…100
    • 1200
    • 100…1000
    • MC2H-VE100
    • MC210333
  • 160 A/150 kA
    • 80…160
    • 1920
    • 160…1600
    • MC2H-VE160
    • MC216333
  • 250 A/150 kA
    • 125…250
    • 3000
    • 250…2500
    • MC2H-VE250
    • MC225333

4 POLE (NORMAL BREAKING CAPACITY) 50 kA

  • 100 A/50 kA
    • 50…100
    • 1200
    • 100…1000
    • MC2N-4-VE100
    • MC210243
  • 160 A/50 kA
    • 80…160
    • 1920
    • 160…1600
    • MC2N-4-VE160
    • MC216243
  • 250 A/50 kA
    • 125…250
    • 3000
    • 250…2500
    • MC2N-4-VE250
    • MC225243

4 POLE (HIGH BREAKING CAPACITY) 150 kA

  • 100 A/150 kA
    • 50…100
    • 1200
    • 100…1000
    • MC2H-4-VE100
    • MC210343
  • 160 A/150 kA
    • 80…160
    • 1920
    • 160…1600
    • MC2H-4-VE160
    • MC216343
  • 250 A/150 kA
    • 125…250
    • 3000
    • 250…2500
    • MC2H-4-VE250
    • MC225343

CIRCUIT BREAKER UP TO 250A 3-/4 POLE      WITH DELAYED ELECTRONIC RELEASE    TYPES MC2N-VE, MC2H-VE, MC2N-4-VE, MC2H-4-VE

SWITCH DISCONNECTOR UP TO 250A TYPES MC2-PN, MC2-PN-4, MC2-N, MC2-N-4

  • 3- and 4-pole versions
  • Rated uninterrupted current up to 250A
  • Switch disconnector, MC2-PN type, two switch positions 0/I, cannot be tripped remotely
  • Switch disconnector MC2-N, with trip setting “0”; “+”; “I”, can be tripped remotely with undervoltage/shunt release
  • Screw terminals as standard, box terminals as accessories
  • Remote trip MC2-N can also be combined with remote operator MC-XR
  • Main switch characteristics including positive drive according to IEC/EN 60204 & VDE 0113
  • Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. Protection against accidental contact accord. to VDE 0160 Part 100
  • Meets IEC/EN 60947-2
  • Rated uninterrupted current = Rated current
  • Rated short-circuit breaking capacity values:cmI 5,5kA
  • Rated short-time withstand current: Icw 3,5kA

SWITCH DISCONNECTOR UP TO 250A TYPES MC2-PN, MC2-PN-4, MC2-N, MC2-N-4

RATED UNINTERRUPTED CURRENT

  • MAX. BACK-UP FUSE (gL) FOR SWITCH DISCONNECTOR (AgL)
  • TYPE
  • ORDER NO.

3 POLE CANNOT BE TRIPPED REMOTELY

  • 160 A
    • 250
    • MC2-PN-160
    • MC216034
  • 200 A
    • 250
    • MC2-PN-200
    • MC220034
  • 250 A
    • 250
    • MC2-PN-250
    • MC225034

4 POLE CANNOT BE TRIPPED REMOTELY

  • 160 A
    • 250
    • MC2-PN-4-160
    • MC216044
  • 200 A
    • 250
    • MC2-PN-4-200
    • MC220044
  • 250 A
    • 250
    • MC2-PN-4-250
    • MC225044

3 POLE CAN BE TRIPPED REMOTELY

  • 160 A
    • 250
    • MC2-N-160
    • MC216035
  • 200 A
    • 250
    • MC2-N-200
    • MC220035
  • 250 A
    • 250
    • MC2-N-250
    • MC225035

4 POLE CAN BE TRIPPED REMOTELY

  • 160 A
    • 250
    • MC2-N-4-160
    • MC216045
  • 200 A
    • 250
    • MC2-N-4-200
    • MC220045
  • 250 A
    • 250
    • MC2-N-4-250
    • MC225045

SWITCH DISCONNECTOR UP TO 250A    TYPES MC2-PN, MC2-PN-4, MC2-N, MC2-N-4

RESIDUAL CURRENT (RCD)RELEASE UP TO 250A TYPES MC2-4-XFI, MC2-4-XFIA

  • Direct mounting on 4 pole MC2 circuit breaker and MC2-N switch disconnector
  • Type MC2-4-XFI pulse current sensitive accord. to core-balance principle
  • Specifications to IEC/EN 60947-2
  • Bottom mounting up to 250 A

TECHNICAL DATA

  • Independent of mains- and auxiliary voltage, Ue = 280 V – 690 V 50/60 Hz
  • Auxiliary contact: 1 N/O, 1 N/C reset via reset feature
  • Type XFI(A)30: Rated fault currentΔIn = 0,03 A, suitable for human protection to Annex B of IEC/EN 60947-2 and VDE 664 Parts 2 and 3
  • Type XFI: Rated fault current ΔIn = 0,1-0,3-1-3 A, time-delay tv = 60-150-300-450 ms, Type XFIA: Rated fault currentΔnI = 0,1-0,3-1 A, time-delay tv = 60-150-300-450 ms, AC/DC current sensitivity accord. to core-balance principle (0–200 kHz)
  • Internal supply voltage Ue = 50–400 V
  • Note that response threshold is dependent on frequency!

RESIDUAL CURRENT (RCD)RELEASE UP TO 250A TYPES MC2-4-XFI, MC2-4-XFIA

DESCRIPTION

  • TYPE
  • ORDER NO.

4 POLE BOTTOM MOUNTING PULSE-CURRENT SENSITIVE

  • FI-human protection 30 mA IΔn for MC2-4
    • MC2-4-XFI30
    • MC296719
  • FI 0.1-3 A IΔn for MC2-4
    • MC2-4-XFI
    • MC296720

4 POLE BOTTOM MOUNTING AC/DC CURRENT SENSITIVITY

  • FI-human protection 30 mA IΔn for MC2-4
    • MC2-4-XFIA30
    • MC292345
  • FI 0.1-1 A IΔn for MC2-4
    • MC2-4-XFIA
    • MC292346

RESIDUAL CURRENT (RCD)RELEASE UP TO 250A    TYPES MC2-4-XFI, MC2-4-XFIA

SOCKET UND PLUG-IN MODULE FOR MC2

  • 3- and 4-pole versions
  • FOR CIRCUIT BREAKER MC2 AND SWITCH DISCONNECTOR MC2-N
  • Plug-in module only available in combination with switch
  • Socket can be ordered separately, available pre-assembled
  • Order control circuit plug unit separately

TECHNICAL DATA

  • In max. at 40 °C:
  • 230A MC2
  • 250A MC2-E (electronic release)

SOCKET UND PLUG-IN MODULE FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

SOCKET

  • Socket, 3 pole
    • MC2-XSVS
    • MC296699
  • Socket, 4 pole
    • MC2-4-XSVS
    • MC296700

PLUG-IN MODULE

  • Plug-in module, 3 pole (add an S to end of switch part number if supplied with switch)
    • MC2-XSVE
  • Plug-in module, 4 pole (add an S to end of switch part number if supplied with switch)
    • MC2-4-XSVE

ACCESSORIES FOR PLUG-IN STYLE ASSEMBLY MC2/MC2-N

  • Control circuit plug unit for auxiliary contact
    • MC2-XSVHI
    • MC296705
  • Control circuit plug unit undervoltage-/shunt release and remote operator
    • MC2-XSVR
    • MC296706

SOCKET UND PLUG-IN MODULE FOR MC2

STANDARD AUXILIARY CONTACT / TRIP-INDICATING AUXILIARY CONTACT TYPE M22

  • Breaking with the main contacts, used for indicating and interlocking tasks
  • General trip indication “+” with trip due to voltage release,overload release or short-circuitrelease

TECHNICAL DATA

  • Breaking capacity: AC15: 4 A / 230 VAC
  • DC13: 3 A / 24 VDC

TIPS & TRICKS

  • The trip-indicating auxiliary contact is the same contact as the standard auxiliary contact. It derives its function from where it is installed (alarm contact on left).
  • Maximum component installation with auxillary contacts:
    • 2 x Standard auxiliary contact (HIN) M22-K. or M22-CK...
    • + 1 x Trip-indicating contact (HIA) M22-K. or M22-CK...

STANDARD AUXILIARY CONTACT / TRIP-INDICATING AUXILIARY CONTACT TYPE M22

DESCRIPTION

  • TYPE
  • ORDER NO.

1 NO contact with screw terminals

  • M22-K10
  • MM216376

1 NC contact with screw terminals

  • M22-K01
  • MM216378

2 NO contacts with cage clamp terminals

  • M22-CK20
  • MM107898

2 NC contacts with cage clamp terminals

  • M22-CK02
  • MM107899

STANDARD AUXILIARY CONTACT / TRIP-INDICATING AUXILIARY CONTACT    TYPE M22

EARLY-MAKE AUXILIARY CONTACT TYPE MC2-XHIVL

  • For interlock- and load-shedding circuits as well as for early make of undervoltage release in main switch/Emergency stop applications.

TECHNICAL DATA

  • Early-make during switch on and off (manual switch): approx. 20 ms
  • Not in connection with undervoltage release MC2-XU... or shunt release MC2-XA...
  • Breaking capacity:
    • AC15: 4 A / 230 VAC
    • DC13: 3 A / 24 VDC

EARLY-MAKE AUXILIARY CONTACT TYPE MC2-XHIVL

DESCRIPTION

  • TYPE
  • ORDER NO.

Early-make auxiliary contact, 2 NO

  • MC2/3-XHIV
  • MC299430

EARLY-MAKE AUXILIARY CONTACT    TYPE MC2-XHIVL

UNDERVOLTAGE RELEASE TYPES MC2-XU

  • Non-delayed breaking of circuit breaker MC/ switch disconnector MC-N when the control voltage drops below 35 % - 70% Us.
  • For use in Emergency stop devices in connection with Emergency stop buttons
  • Installed in breaker
  • Without auxiliary contact

TECHNICAL DATA

When the undervoltage release is de-energized, accidental contact with the main contacts of the switch is safely prevented during attempts to switch on. Undervoltage releases cannot be installed at the same time with shunt releases or early-make auxiliary contact, type MC2-XHIV.

UNDERVOLTAGE RELEASE TYPES MC2-XU

VOLTAGE

  • TYPE
  • ORDER NO.

24 VAC

  • Screw terminals
  • MC2/3-XU24AC
  • MC299491

24 VDC

  • Screw terminals
  • MC2/3-XU24DC
  • MC299509

208-240 V AC

  • Screw terminals
  • MC2/3-XU208-240AC
  • MC299499

380-440 V AC

  • Screw terminals
  • MC2/3-XU380-440AC
  • MC299501

Other voltage variants available upon request.

UNDERVOLTAGE RELEASE    TYPES MC2-XU

UNDERVOLTAGE RELEASE WITH TWO EARLY-MAKE AUXILIARY CONTACTS TYPES MC2-XUHIV

  • With 2 early-make auxillary contacts
  • For early-make of the undervoltage release in main switch applications and for interlock- and load-shedding circuits
  • Installed in breaker
  • Other voltages and connection versions available on request

TECHNICAL DATA

When the undervoltage release is de-energized, accidental contact with the main contacts of the switch is safely prevented during attempts to switch on. Early-make of auxillary contacts during switch on and off (20ms). Undervoltage releases cannot be installed simultaneously with shunt releases or early-make auxiliary contact, type MC2-XHIV.

UNDERVOLTAGE RELEASE WITH TWO EARLY-MAKE AUXILIARY CONTACTS TYPES MC2-XUHIV

VOLTAGE

  • TYPE
  • ORDER NO.

208 - 240 VAC

  • screw terminals
  • MC2/3-XUHIV230V
  • MC299591

380 - 440 VAC

  • screw terminals
  • MC2/3-XUHIV400V
  • MC299594

Other voltage variants available upon request.

UNDERVOLTAGE RELEASE WITH TWO EARLY-MAKE AUXILIARY CONTACTS    TYPES MC2-XUHIV

UNDERVOLTAGE RELEASE, OFF-DELAY TYPES MC-UVU, MC-XUV

  • Voltage drops less than 0,07–16 s do not cause MC circuit breakers or N switch disconnectors to trip.
  • Suitable for voltages:
    • 220 – 240 VAC 50/60 Hz
    • 380 – 440 VAC 50/60 Hz
    • 480 – 550 VAC 50/60 Hz
    • 24 VAC/DC

TECHNICAL DATA

  • Time-delay adjustable between 70 ms – 4 s
  • With additional external capacitor:
    • 30.000 μF≥35 V to 8 s
    • 90.000 μF≥35 V to 16 s
  • 1 x special release MC2-XUV required.
  • Cannot be installed simultaneously with early-make auxiliary contact MC2-XHIV... or shunt release MC2-XA....
  • Time-delay device for separate mounting (Fastening: DIN rail or screws).
  • For other operating voltages, please use a control transformer.

UNDERVOLTAGE RELEASE, OFF-DELAY TYPES MC-UVU, MC-XUV

NAME

  • TYPE
  • ORDER NO.

Time-delay unit

  • MC-UVU
  • MC196154

Special undervoltage release for time-delay unit MC2

  • MC2/3-XUV
  • MC295927

Other voltage variants available upon request.

UNDERVOLTAGE RELEASE, OFF-DELAY    TYPES MC-UVU, MC-XUV

SHUNT RELEASE TYPES MC2-XA

  • Without auxiliary contact
  • Switches are tripped by a voltage pulse or by the application of uninterrupted voltage

TECHNICAL DATA

  • When the shunt release is energized, accidental contact with the main contacts of the switch is safely prevented during attempts to switch on.
  • Shunt release cannot be installed simultaneously with undervoltage releases or early-make auxiliary contact MC1-XHIV.

SHUNT RELEASE TYPES MC2-XA

VOLTAGE

  • TYPE
  • ORDER NO.

24 VAC/DC

  • MC2/3-XA24V
  • MC299754

208 - 250 VAC/DC

  • MC2/3-XA230V
  • MC299763

Other voltage variants available upon request.

SHUNT RELEASE    TYPES MC2-XA

REMOTE OPERATOR FOR MC2

  • Remote operator can be combined with circuit breaker MC and switch disconnector MC-N, but not with switch disconnector MC-PN.
  • Do not deactivate switch simultaneously via remote control and trip via undervoltage/shunt release.

TECHNICAL DATA

  • On/Off breaking and reset by means of 2-wire or 3- wire control.
  • MC299832 can be synchronized
  • Breaking time On:≤60 ms for MC2-XR208-240AC≤170 ms for MC2-XRD208-240AC
  • Local manual breaking possible
  • Pause between Off and On:
    • 3 secs. Command is ignored
  • Function of Terminal 75:
    • Ready for activation signal when the cover is closed and not locked.
      • AC-15: 2 A/400 V
      • DC-13: 0,2 A/220 V

REMOTE OPERATOR FOR MC2

VOLTAGE

  • TYPE
  • ORDER NO.

208 - 240 V AC

  • MC2-XR208-240AC
  • MC299832

208 - 240 V AC mech. interlock not possible

  • MC2-XRD208-240AC
  • MC299833

Extra cover for 4-pole switches

  • MC2-XAVPR
  • MC296677

REMOTE OPERATOR FOR MC2

MECHANICAL INTERLOCK FOR (DOOR COUPLING) ROTARY HANDLES FOR MC2

  • Rotary handle on switch or door coupling rotary handle additionally required.
  • Cannot be combined with remote operator or door frame.
  • At least 2 interlocking modules are required in order to construct a mechanical interlocking circuit. See Page 142 for possible combinations and variations of interlocking circuits. Bowden cable to be ordered separately.

MECHANICAL INTERLOCK FOR (DOOR COUPLING) ROTARY HANDLES FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Mechanical interlock

  • MC2-XMV
  • MC291582

Bowden cable 225 mm

  • MC-XBZ225
  • MC191585

Bowden cable 600 mm

  • MC-XBZ600
  • MC191586

Bowden cable 1000 mm

  • MC-XBZ1000
  • MC191587

MECHANICAL INTERLOCK FOR (DOOR COUPLING) ROTARY HANDLES FOR MC2

MECHANICAL INTERLOCK WITH REMOTE OPERATOR FOR MC2

  • For 2 switches of the same or next frame size side by side
  • Side-by-side mounting
  • Mounted on top of each other, long version
  • Contains parts for 2 switches
  • Remote operator also required
  • For maximum breaking distance
  • Not for MC2-XRD208-240AC

NOTES

  • Cannot be combined with rotary handles, door coupling rotary handles and early-make auxiliary contacts.

MECHANICAL INTERLOCK WITH REMOTE OPERATOR FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Mechanical interlock for MC2

  • MC2-XMVR
  • MC294543

Mechanical interlock for MC2 long version

  • MC2-MVRL
  • MC294548

Mechanical interlock for MC2/3

  • MC2/3-XMVR
  • MC294544

Mechanical interlock for MC2/3, long version

  • MC2/3-XMVRL
  • MC294549

MECHANICAL INTERLOCK WITH REMOTE OPERATOR FOR MC2

ROTARY HANDLES DIRECTLY ON SWITCH FOR MC2

  • Complete with rotary drive
  • Can also be combined with door frame

TECHNICAL DATA

Available in the following versions:

  • Type MC.-XDV
    • Lockable in the “0” position (up to three padlocks), black/grey
  • Type MC.-XDVR
    • Lockable in the “0” position (up to three padlocks), Emergency stop red/yellow
  • Type MC.-XDTV
    • Lockable in the “0” position on handle, modification also available in “1” position, black/grey
  • Type MC.-XDTVR
    • Lockable in “0” position, Emergency Stop red/yellow

Version comes with door interlock:

  • Door frame supplied with door interlock
  • Rotary handle can be rotated 90° for switches mounted horizontally
  • In the ON position, can be defeated from the outside using a 1 mm pin
  • Cannot be defeated in the locked OFF and ON positions
  • Door can be opened in OFF
  • Can only be switched on when door closed

ROTARY HANDLES DIRECTLY ON SWITCH FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Lockable rotary handle for MC2, black/grey

  • MC2-XDV
  • MC290127

Lockable rotary handle for MC2, Emergency stop red/yellow

  • MC2-XDVR
  • MC290137

Rotary handle for MC2 with door interlock, lockable, black/grey

  • MC2-XDTV
  • MC290133

Rotary handle for MC2 with door interlock, lockable, Emergency stop red/yellow

  • MC2-XDTVR
  • MC290144

ROTARY HANDLES DIRECTLY ON SWITCH FOR MC2

DOOR COUPLING ROTARY HANDLE FOR MC2

  • Complete unit includes rotary drive and coupling parts
  • Degree of Protection IP66
  • Rotary handle can be rotated 90° for horizontally-mounted switches
  • Cannot be defeated in the locked OFF and ON positions
  • Can be modified when in the unlocked ON position, can be defeated from the outside with a screwdriver
  • Door can be opened in OFF
  • External warning plate/designation plate can be clipped on

NOTES

  • Order extension shaft separately!

TECHNICAL DATA

  • Available in the following versions:
    • Type MC.-XTVD
      • Lockable in the “0” position on handle with up to three padlocks, with door interlock, black/grey
    • Type MC.-XTVDV
      • Lockable in the “0” position on handle and switch, with up to three padlocks, with door interlock, black/grey
    • Type MC.-XTVDVR
      • Lockable in the “0” position on handle and switch with up to three padlocks, with door interlock, Emergency stop red/yellow

DOOR COUPLING ROTARY HANDLE FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

 

Door coupling rotary handle for MC2 with door interlock, lockable, black/grey

  • MC2-XTVD
  • MC290168

Door coupling rotary handle for MC2 with door interlock, lockable, “0”, “1”, black/grey

  • MC2-XTVDV
  • MC290174

Door coupling rotary handle for MC2 with door interlock, lockable, Emergency stop red/yellow

  • MC2-XTVDVR
  • MC290180

DOOR COUPLING ROTARY HANDLE FOR MC2

EXTENSION SHAFT FOR MC2

  • for maximum cabinet depths of 400 or 600 mm
  • Can be cut to required length

EXTENSION SHAFT FOR MC2

DESCRIPTION

  • CABINET DEPTH
  • TYPE
  • ORDER NO.

Extension shaft for MC2 max.

  • 400 mm max. 400 mm
  • MC1/2-XV4
  • MC191232

Extension shaft for MC2 max.

  • 600 mm max. 600 mm
  • MC1/2-XV6
  • MC190191

EXTENSION SHAFT FOR MC2

BOX TERMINALS FOR MC2

  • Conversion kit for switches with screw connection
  • Contains parts for one switch side
  • Installed within the switch housing
  • Use cover plate MC.-XSKA
  • Terminal capacities:
    • Copper lines 1 x 4 – 185 mm2
    • Copper cables 2 x 4 – 70 mm2

BOX TERMINALS FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Box terminal up to 160 A (contains 3 pcs.) for MC2

  • MC2-160-XKC
  • MC292240

Box terminal up to 250 A (contains 3 pcs.) for MC2

  • MC2-250-XKC
  • MC292244

Box terminal up to 160 A (contains 4 pcs.) for MC2-4

  • MC2-4-160-XKC
  • MC296755

Box terminal up to 250 A (contains 4 pcs.) for MC2-4

  • MC2-4-250-XKC
  • MC296756

BOX TERMINALS FOR MC2

SCREW CONNECTION FOR MC2

  • Standard connection for all MC2, MC2-PN and MC2-N switches
  • Conversion kit for switches with box terminal
  • Installed inside switch housing
  • Contains parts for one switch side located at top or bottom 3- or 4 pole switches
  • Terminal capacities:
  • Copper cable lug 1 x 4 – 185 mm2,2 x 4 – 70 mm2
  • Aluminium cable lug 1 x 10 – 50 mm2, 2 x 10 – 50 mm2

SCREW CONNECTION FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Screw connection, 3 pole for MC2

  • MC2-XKS
  • MC290030

Screw connection, 4 pole for MC2-4

  • MC2-4-XKS
  • MC296750

TUNNEL TERMINAL FOR MC2

TUNNEL TERMINAL FOR MC2

  • Contains parts for one switch side, top or bottom
  • Comes with terminal for control circuit cabling as standard for 1 x 0,75 – 2,5 mm2 or 2 x 0,75 – 1,5 mm2
  • Terminal capacities:
    • Copper cable, AIuminium cable 1 x 16 – 185 mm2
  • Installed outside switch housing

TECHNICAL DATA

  • For copper and aluminium cables, as ordered, up to 240 mm2
  • Includes cover plate
  • Stranded round conductor / stranded sector-shaped conductor

TUNNEL TERMINAL FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Tunnel terminal 185 mm2, 3 pcs. included, for MC2

  • MC2-XKA
  • MC291457

Tunnel terminal 185 mm2, 4 pcs. included, for MC2-4

  • MC2-4-XKA
  • MC291458

SCREW CONNECTION FOR MC2

REAR CONNECTION FOR MC2

  • Contains parts for one switch side, top or bottom
  • Terminal capacities:
    • Copper cable lug 1 x 4 – 185 mm2, 2 x 4 – 70 mm2
    • Aluminium cable lug 1 x 10 – 50 mm2, 2 x 10 – 50 mm2

REAR CONNECTION FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Rear connection, 3 pole MC2

  • MC2-XKR
  • MC296765

Rear connection, 4 pole MC2-4

  • MC2-4-XKR
  • MC296768

REAR CONNECTION FOR MC2

CONTROL CIRCUIT TERMINAL FOR MC2

  • Contains parts for two terminals located at top or bottom for 3/ 4 pole switches
  • Included with tunnel terminal
  • Degree of protection IP1X
  • Terminal capacities:
    • Screw connection 1 x 0,75 – 2,5 mm2, 2 x 0,75 – 1,5 mm2
    • Box terminal 1 x 0,75 – 2,5mm2, 2 x 0,75 – 1,5 mm2

CONTROL CIRCUIT TERMINAL FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Control circuit terminal for box terminal MC2

  • MC2-XSTK
  • MC196739

Control circuit terminal for screw connection MC2

  • MC2-XSTS
  • MC290156

CONTROL CIRCUIT TERMINAL FOR MC2

TERMINAL COVER FOR MC2

  • Protection against accidental contact when using cable lugs, rails or Tunnel terminals
  • Contains parts for one switch side located at top or bottom 3- or 4 pole switches
  • Degree of protection IP4X front, side and rear, IP1X on the connection side when using insulated conductor material
  • Cover plate included with tunnel terminals

TERMINAL COVER FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Terminal cover, 3 pole for MC2

  • MC2-XKSA
  • MC290038

Terminal cover, 4 pole for MC2-4

  • MC2-4-XKSA
  • MC296770

TERMINAL COVER FOR MC2

CABLE LUG FOR MC2

  • Special cable lug in slimline design
  • Cable lugs must be insulated when using without a cover plate.

CABLE LUG FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Cable lug 95 mm2

  • MC2-XKS95
  • MC299775

Cable lug 120 mm 2

  • MC2-XKS120
  • MC299776

Cable lug 150 mm 2

  • MC2-XKS150
  • MC299777

Cable lug 185 mm 2

  • MC2-XKS185
  • MC290032

CABLE LUG FOR MC2

CONNECTION COVER, KNOCKOUT FOR BOX TERMINAL MC2

  • Contains parts for a terminal located at top or bottom for 3 or 4 pole switches
  • Increases protection against accidental contact (simplified finger protection)

CONNECTION COVER, KNOCKOUT FOR BOX TERMINAL MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Terminal cover, knockout, 3 pole for MC2

  • MC2-XKSFA
  • MC294640

Terminal cover, knockout, 4 pole for MC2

  • MC2-4-XKSFA
  • MC294641

CONNECTION COVER, KNOCKOUT FOR BOX TERMINAL MC2

IP2X FINGER PROTECTION FOR DIRECT-MOUNTED MC2 SWITCHES

  • Increases the protection against accidental contact to IP2X
  • Protection when reaching into the cable connection area when cables are connected in box terminal
  • For 2 conductors, minimum cross-section equals 25 mm2
  • MC2-XIPA and MC2-4-XIPA only in connection with cover plate MC2(-4)-XKSA

IP2X FINGER PROTECTION FOR DIRECT-MOUNTED MC2 SWITCHES

DESCRIPTION

  • TYPE
  • ORDER NO.

FOR BOX TERMINAL

  • Finger protection, 3 pole for MC2
    • MC2-XIPK
    • MC296743
  • Finger protection, 4 pole for MC2-4
    • MC2-4-XIPK
    • MC296744

FOR TERMINAL COVER

  • Finger protection, 3 pole for MC2
    • MC2-XIPA
    • MC296777
  • Finger protection, 4 pole for MC2-4
    • MC2-4-XIPA
    • MC296778

IP2X FINGER PROTECTION FOR DIRECT-MOUNTED MC2 SWITCHES

INSULATED ENCLOSURE XCI

  • For switches with box terminals only, for direct cable connection
  • With door coupling rotary handle
  • Complete unit including all necessary functional parts
  • Degree of protection IP65
  • Comes with gland plates

TECHNICAL DATA

  • Enclosure suitable for installation of circuit-breakers and switch-disconnectors for separate mounting with top and bottom
  • cable entry. Includes fixing straps for wall mounting.
  • Short circuit protection at 415 V 50/60 Hz to 10 kA.
  • Not in combination with remote operator, plug-in- or withdrawable unit.
  • Additional insulated terminals for 4 or 5 pole must be ordered separately.

Available in the following versions:

  • Standard, black/grey
    • Lockable in the “0” position at handle with up to 3 padlocks. Additionally with cover interlock.
  • For Emergency stop, red/yellow
    • Lockable on handle and switch with up to 3 padlocks

INSULATED ENCLOSURE XCI

DESCRIPTION

  • MAX. RATED UNINTERRUPTED CURRENT
  • TYPE
  • ORDER NO.

STANDARD, BLACK/GREY

  • Insulated enclosure for MC2 and MC2-4
    • ≤ 200 A
    • MC2-XCI43-TVD
    • MC291524
  • Insulated enclosure for MC2 and MC2-4
    • ≤ 250 A
    • MC2-XCI45-TVD
    • MC290418

FOR EMERGENCY STOP, RED/YELLOW

  • Insulated enclosure for MC2 and MC2-4
    • ≤ 200 A
    • MC2-XCI43-TVDR
    • MC291529
  • Insulated enclosure for MC2 and MC2-4
    • ≤ 250 A
    • MC2-XCI45-TVDR
    • MC299356

INSULATED ENCLOSURE XCI

ADDITIONAL INSULATED TERMINALS FOR MC2

  • For looping through the neutral and earth conductor
  • 1 pole

ADDITIONAL INSULATED TERMINALS FOR MC2

DESCRIPTION

  • TERMINAL CAPACITY
  • TYPE
  • ORDER NO.

Additional insulated terminal 32 A

  • Fine-wired 1 x (1,5-6 mm2)
  • K10/1
  • MC193827

Additional insulated terminals 63 A

  • Fine-wired 1 x (6-16 mm 2), stranded 1 x (16-25 mm2)
  • K25/1
  • MC196200

Additional insulated terminals 100 A

  • Fine-wired 1 x (10-35 mm 2), stranded 1 x (16-50 mm2)
  • K50/1
  • MC198573

Additional insulated terminal 160 A

  • stranded 1 x (16-95 mm 2)
  • K95/1N/BR
  • MC192336

Additional insulated terminal 250 A

  • stranded, 1 x (35-150mm 2), 2 x (16-70mm2)
  • K150/1BR
  • MC294709

ADDITIONAL INSULATED TERMINALS FOR MC2

DEVICE ADAPTERS FOR CIRCUIT-BREAKERS AND SWITCH-DISCONNECTORS FOR 60 mm BUSBAR SYSTEM MC2

  • For mounting on flat copper rails 12 x 5 mm to 30 x 10 mm
  • Double T and triple T profile
  • Mounted via terminal-, screw fixing
  • Rated operational voltage Ue: 690 V
  • Cover plate also required (MC-XKR)

TECHNICAL DATA

  • MC 2 up to 250 A:
  • Top or bottom connection to system as required
  • Cover plate MC2-XKR4 required

DEVICE ADAPTERS FOR CIRCUIT-BREAKERS AND SWITCH-DISCONNECTORS FOR 60 mm BUSBAR SYSTEM MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

60 mm busbar adapter 250 A, 3 pole

  • 32140
  • MC291400

Cover plate for component adapter, 3 pole

  • MC2-XKR4
  • MC291666

4 pole adapter with cover plate

  • MC3-4XKR13
  • upon request

DEVICE ADAPTERS FOR CIRCUIT-BREAKERS AND    SWITCH-DISCONNECTORS FOR 60 mm BUSBAR SYSTEM MC2

DOOR SEALING FRAME FOR MC2

  • For toggle levers, rotary handles with rotary drive and remote operator
  • Degree of protection IP40
  • For rectangular cut-out on doors and enclosures with material thicknesses of 1,5 – 5 mm
  • External warning plate/designation plate can be clipped on

DOOR SEALING FRAME FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Door sealing frame for MC2

  • MC2-XBR
  • MC290197

DOOR SEALING FRAME FOR MC2

TOGGLE LEVER LOCKING DEVICE FOR MC2

  • Off position lockable with up to 3 padlocks (hasp thickness 4 – 8 mm)
  • Cannot be combined with Insulating surround

TOGGLE LEVER LOCKING DEVICE FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Toggle lever locking device for MC2

  • MC2/3-XKAV
  • MC290201

TOGGLE LEVER LOCKING DEVICE FOR MC2

SPACERS FOR MC2

  • Enables fast and low-priced adjustment of various frame sizes with/without rotary handle or remote operator at same front depth
  • Grid depth 17,5 mm, thread M4
  • Each set contains 4 x spacers
  • Maximum component installation 4 pcs. per fastening screw
  • 2 fastening screws included for each circuit breaker MC2

SPACERS FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Spacers for MC2

  • MC2-XAB
  • MC190203

SPACERS FOR MC2

CLIP PLATE FOR MC2

  • Enables snap fit of circuit breakers / switch disconnectors to DIN rail (75 mm top-hat rail)
  • Not suitable for switches with remote operator

CLIP PLATE FOR MC2

DESCRIPTION

  • TYPE
  • ORDER NO.

Clip plate for MC2

  • MC2-XC75
  • MC290215