Slim fitting suitable for all industry applications. Easy to install within narrow frame structures. Wide 14mm sensing high tolerance to misalignment. LED indication Up to EN 954-1 Cat.4 with safety relay 2NC 1NO circuits Quick connect versions
Part No | Type | Cable Length | Circuits |
115001 | Idecode CPC | 2M | 2NC |
115002 | Idecode CPC | 5M | 2NC |
115003 | Idecode CPC | 10M | 2NC |
115004 | Idecode CPC | QC-M12 | 2NC |
115005 | Idecode CPC | 2M | 2NC 1NO |
115006 | Idecode CPC | 5M | 2NC 1NO |
115007 | Idecode CPC | 10M | 2NC 1NO |
115008 | Idecode CPC | QC-M12 | 2NC 1NO |
Compact yet robust fitting suitable for all small guard applications LED indication Hygienic screw covers ensure suitability for Food Processing washdown. Cast effective interlock solution Wide sensing at 10mm High Specification polyester housing backplate Can be mounted unobtrusively in channels or behind doors – left or right cable exit 2NC 1NO circuits – up to EN 954-1 Cat.4 with Safety Relay
Part No | Type | Cable Length | Circuits |
114101 | MPC Cable Right | 2M | 2NC |
114102 | MPC Cable Right | 5M | 2NC |
114103 | MPC Cable Right | 10M | 2NC |
114104 | MPC Cable Right | QC-M12 | 2NC |
114105 | MPC Cable Right | 2M | 2NC 1NO |
114106 | MPC Cable Right | 5M | 2NC 1NO |
114107 | MPC Cable Right | 10M | 2NC 1NO |
114108 | MPC Cable Right | QC-M12 | 2NC 1NO |
114109 | MPC Cable Left | 2M | 2NC |
Robust Stainless Steel 316 enclosure designed to survive the tough environments of Food and Pharmaceutical applications. LED indication. Survives high pressure hosing at high temperature. High temperature specification 105C. Wide 14mm sensing and high tolerance to misalignment. Universal fitting – established 22mm fixing footprint suitable for most general applications. Up to EN 954-1 Cat.4 with safety relay. 2NC 1NO circuits. Quick connect versions.
Part No | Type | Cable Length | Circuits |
139001 | Hygiecode SMC | 2M | 2NC |
139002 | Hygiecode SMC | 5M | 2NC |
139003 | Hygiecode SMC | 10M | 2NC |
139004 | Hygiecode SMC | QC-M12 | 2NC |
139005 | Hygiecode SMC | 2M | 2NC 1NO |
139006 | Hygiecode SMC | 5M | 2NC 1NO |
139007 | Hygiecode SMC | 10M | 2NC 1NO |
139008 | Hygiecode SMC | QC-M12 | 2NC 1NO |
Part No | Type | Cable Length | Circuits |
110001 | Eurocode LPC | 2M | 2NC |
110002 | Eurocode LPC | 5M | 2NC |
110003 | Eurocode LPC | 10M | 2NC |
110004 | Eurocode LPC | QC-M12 | 2NC |
110005 | Eurocode LPC | 2M | 2NC 1NO |
110006 | Eurocode LPC | 5M | 2NC 1NO |
110007 | Eurocode LPC | 10M | 2NC 1NO |
110008 | Eurocode LPC | QC-M12 | 2NC 1NO |
Universal fitting – established 22mm fixing footprint suitable for most general applications. Withstands environments where high humidity or hose down is required. Durable polyester housing. Wide 14mm Sensing and high tolerance to misalignment. Up to EN 954-1 Cat.4 with safety relay. 2NC 1NO circuits. Quick connect versions.
Part No | Type | Cable Length | Circuits |
111001 | Idecode SPC | 2M | 2NC |
111002 | Idecode SPC | 5M | 2NC |
111003 | Idecode SPC | 10M | 2NC |
111004 | Idecode SPC | QC-M12 | 2NC |
111005 | Idecode SPC | 2M | 2NC 1NO |
111006 | Idecode SPC | 5M | 2NC 1NO |
111007 | Idecode SPC | 10M | 2NC 1NO |
111008 | Idecode SPC | QC-M12 | 2NC 1NO |
We would be delighted to offer free application advice, technical information on products, free quotations and delivery information.