TYPE PMV (LIGHTLY COMPACTED)

TYPE PMV (LIGHTLY COMPACTED)

Cartridge Heaters (PDF datasheet)Specials, product enquiry and further information (Contact us form)

CONICAL SHAPE, TYPE HLPK

Characteristics

The lightly compacted cartridge heaters of this series distinguish themselves by a higher immunity against mechanical shock, and by a substantially longer useful life as compared with noncompacted metal sheathed cartridge heaters of the same surface load. They are suitable for heating liquids, gaseous and solid media and resist arduous service conditions in industrial applications.

Technical Data

similar to the high performance cartridge heaters type HLP, however:

Maximum surface load: approx. 6,5 W/cm2 (on the sheath)
Tolerances: Diameter: +0,2 mm of the groundless covering.
Upon request these can be ground to finer tolerances -0,02 to 0,08 mm
Length: 1.5% at least, however 2 mm
Capacity: 10%

Please note

Cartridge heaters type PMV are only produced in stock types.

STOCK TYPE HEATERS

  • Diameter
    • Length
    • Power in W at 230 V
    • Articel-No.
  • 10 mm
    • 100
    • 125
    • 120 421
  • 10 mm
    • 130
    • 200
    • 120 422
  • 10 mm
    • 160
    • 250
    • 120 423
  • 12,5 mm
    • 100
    • 160
    • 120 424
  • 12,5 mm
    • 130
    • 220
    • 120 425
  • 12,5 mm
    • 160
    • 315
    • 120 426
  • 12,5 mm
    • 200
    • 400
    • 120 427
  • 16,0 mm
    • 100
    • 200
    • 120 428
  • 16,0 mm
    • 130
    • 280
    • 120 429
  • 16,0 mm
    • 160
    • 350
    • 120 430
  • 16,0 mm
    • 200
    • 450
    • 120 431
  • 16,0 mm
    • 250
    • 560
    • 120 432
  • 16,0 mm
    • 300
    • 800
    • 120 433
  • 20,0 mm
    • 100
    • 250
    • 120 434
  • 20,0 mm
    • 130
    • 400
    • 120 435
  • 20,0 mm
    • 160
    • 500
    • 120 436
  • 20,0 mm
    • 200
    • 630
    • 120 437
  • 20,0 mm
    • 250
    • 800
    • 120 438
  • 20,0 mm
    • 300
    • 1000
    • 120 439

Installation guidance

The installation is easier than for the high performance heaters due to the lower surface load. Nevertheless please observe the installation instructions given for the HLP type heaters.

Recommended bore hole

  • Nominal diameter
    • 10 mm
      • 10,2+ 0,1 mm
    • 12,5 mm
      • 12,7+ 0,1 mm
    • 16 mm
      • 16,2+ 0,1 mm
    • 20 mm
      • 20,2+ 0,1 mm